Notes for the table of Treatment Rates and Storage Capacities:
*1 Treatment Flow Rates have been calculated from the results of a 225mm diameter large scale laboratory model, with no tidal influences.
*2 Treatment Flow Rates have been calculated by extrapolation from the results of 225mm diameter large scale laboratory tests, with no tidal influences.
*3 Storage capacities for both floatables and solids allow for more than 12 months of typical urban pollutant generation rates for developed areas.
*4 Total floatables capacity includes free oil. Free oil only capacity is included in brackets.
*5 Sum of capacities of floatables storage, treatment, and solid storage zones.
The recommended 'K' value for an Q-Guard™ stormwater treatment device is 1.3, based on pipe full velocity head in the downstream pipe reach. This value is based on a stormwater treatment device operating within a stormwater system for pipe design flow.
|